Identification of the types of preanalytical errors in a hematology laboratory: 1 year study at ESIC hospital, Chennai
Abstract
Objective: To evaluate the common causes of preanalytical errors in a fully automated hematology laboratory.
Methods: Laboratory staff was instructed to record the rejected samples and the causes of such rejections of ward and outpatient samples collected in both wards and laboratory.
Results: Of the 53344 samples received for hematological tests during the one year period from 1.1.2016 to 31.12.2016, 181 samples were rejected for analysis. This accounted for 0.3% of samples collected for hematological tests. The reasons for rejections with their incidences are as follows: Insufficient samples –35.3 %, Clotted sample –25.7 %, Wrong registration –15.0 %, Double registration –11.6 %, Inappropriate container –5.5 %, Sample spillage – 3.9 %.
Conclusion: The overall percentage of rejection in our hematology laboratory is 0.3 % and insufficient sample is the most common cause for rejection. Adequate training, regular maintenance of a record of errors and periodic auditing will result in effective reduction of such errors and hence improvement in the overall performance of laboratory works.
Downloads
References
2. Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem. 2007 Jul;53(7):1338-42. DOI: 10.1373/clinchem.2007.088344. [PubMed]
3. Ranjna Chawla, Binita Goswami, Devika Tayal, Mallika. Identification of the Types of Preanalytical Errors in the Clinical Chemistry Laboratory: 1-Year Study at G.B. Pant Hospital. Lab Med. 2010; 41(2): 89-92. DOI: 10.1309/LM9JXZBMLSVJT9RK.
4. Bonini P, Plebani M, Ceriotti F, Rubboli F. Errors in laboratory medicine. Clin Chem. 2002 May;48(5):691-8. PMID:11978595. [PubMed]
5. Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability: a College of American Pathologists Q-Probes study of 453 laboratories. Arch Pathol Lab Med. 1997 Jan;121(1):19-26. [PubMed]
6. Iman J. Schultz, Lambertus A. Kiemeney, Johannes L. Willems, Dorine W. Swinkels J. Alfred Witjes Jacques B. de Kok, Preanalytic Error Tracking in a Laboratory Medicine Department: Results of a 1-Year Experience, Clin Chem 52, No. 7, 2006; 1442.
7. Wood KE, Nash DB. Mandatory state-based error-reporting systems: current and future prospects. Am J Med Qual 2005;20(6):297-303. DOI:10.1177/1062860605281850.
8. Plebani M. Appropriateness in programs for continuous quality improvement in clinical laboratories. Clin Chim Acta. 2003 Jul 15;333(2):131-9.